Cell cycle anomalies revealed on the DNA content frequency histogram are often observed after different types of cell damage, for example such DNA damage that interrupts the cell cycle progression at certain checkpoints. Such an arrest of the cell cycle progression can lead either to an effective DNA repair, which may prevent transformation of normal into a cancer cell (carcinogenesis), or to cell death, often by the mode of apoptosis. An arrest of cells in G0 or G1 is often seen as a result of lack of nutrients (growth factors), for example after blood serum deprivation.
Cell cycle analysis was first described in 1969 at Los Alamos Scientific Laboratory by a group from the University of California using the technique.
The first protocol for cell cycle analysis using propidium iodide staining was presented in 1975 by Awtar Krishan from Harvard Medical School and is still widely cited today.
Multiparameter analysis of the cell cycle includes, in addition to measurement of cellular DNA content, other cell cycle related constituents/features. The concurrent measurement of cellular DNA and RNA content, or DNA susceptibility to denaturation at low pH using the metachromatic dye acridine orange, reveals the G1Q, G1A, and G1B cell cycle compartments and also makes it possible to discriminate between S, G2 and mitotic cells. The cells in G1Q are quiescent, temporarily withdrawn from the cell cycle (also identifiable as G0), the G1A are in the growth phase while G1B are the cells just prior entering S, with their growth (RNA and protein content, size) similar to that of the cells initiating DNA replication. Similar cell cycle compartments are also recognized by multiparameter analysis that includes measurement of expression of cyclin D1, cyclin E, cyclin A and cyclin B1, each in relation to DNA content Concurrent measurement of DNA content and of incorporation of DNA precursor 5-bromo-2'-deoxyuridine (BrdU) by flow cytometry is an especially useful assay, that has been widely used in analysis of the cell cycle in vitro and in vivo. However, the incorporation of 5-ethynyl-2'-deoxyuridine (EdU), the precursor whose detection offers certain advantages over BrdU, has now become the preferred methodology do detect DNA replicating (S-phase) cells.
such as Triton X-100 or NP-40, or by fixating them in ethanol. Most fluorescent DNA dyes (one of exceptions is Hoechst 33342) are not plasma membrane permeant, that is, unable to pass through an intact cell membrane. Permeabilisation is therefore crucial for the success of the next step, the staining of the cells.
Prior to (or during the staining step) the cells are often treated with RNase A to remove . This is important because certain dyes that stain DNA will also stain RNA, thus creating artefacts that would distort the results. An exception is the metachromatic fluorochrome acridine orange, which under the specific staining protocol can differentially stain both, RNA (generating red luminescence) and DNA (green fluorescence), or in another protocol, after removal of RNA and partial DNA denaturation, to differentially stain double-stranded DNA (green fluorescence) versus single-stranded DNA (red luminescence)3. Aside from propidium iodide and acridine orange, quantifiable dyes that are frequently used include (but are not limited to) DRAQ5, 7-Aminoactinomycin D, DAPI and Hoechst 33342.
|
|